Filter Media Types
Polypropylene (PP), glass fiber (GF), and PES membrane — properties, applications, and selection criteria for high-flow filter elements.
- Polypropylene: broad chemical compatibility, 1–100 µm, nominal filtration
- Glass Fiber: higher efficiency, absolute-rated, ideal for condensate polishing
- PES Membrane: sterilizing grade, pharma applications, FDA compliant
Differential Pressure & Flow Performance
Understanding pressure drop across high-flow filter elements. How element length, micron rating, and media type affect system performance.
- Typical clean ΔP: 0.05–0.15 bar at rated flow
- Change-out threshold: 1.5–2.5 bar depending on application
- 40" elements process up to 110 m³/h per element
Housing Compatibility Guide
R+F replacement filter elements are designed to fit directly into OEM housings. Key dimensions, end cap geometry, and O-ring specifications.
- Standard 6" OD (152 mm) for Pall, Parker, 3M HF, Pentair
- 6.5" OD (165 mm) for 3M 740B/K series — NOT interchangeable
- 226/flat O-ring interface standard across most brands